Home > Socket Error > Wsaeinval Error

Wsaeinval Error

Contents

Typically, though, WinSock generates WSAENETUNREACH when it receives a "host unreachable" ICMP message from a router instead of WSAEHOSTUNREACH. Detailed descriptions: connect(): the operation is underway, but as yet incomplete. here is the relevant code: timeval timeout; fd_set input_set, exc_set; int s, nfds; FD_ZERO(&input_set); FD_ZERO(&exc_set); nfds = 0; timeout.tv_sec = 0; timeout.tv_usec = 0; for(int i = 0; i < MAX_CLIENTS; If select returns immediately, then the select call is considered nonblocking and the standard assumptions for nonblocking calls apply. http://hardwareyellowpages.com/socket-error/wsaeinval.html

Cannot remove a directory that is not empty. Developer suggestions: Handle this as a non-fatal error. WSASYSNOTREADY 10091 Network subsystem is unavailable. Any function that takes a socket as an input parameter--except close socket()--could potentially fail with this error.

Windows Socket Error 10054

Join our community for more solutions or to ask questions. This error is relevant to connect(), but not to send() or sendto() as it is in Berkeley Sockets. WinSock description: No equivalent. Regarding Dan's comments about reducing the microseconds, it seems to work (for me) either way -- setting the timeout to a large microsecond value is equivalent to setting it to a

  1. WSAEINTR 10004 Interrupted function call.
  2. Returned when a system call that should never fail does fail.
  3. Developer suggestion: are you trying to use an optional feature?
  4. Subscribe to GameDev.net's newsletters to receive the latest updates and exclusive content.
  5. strangely enough, it works in another program i wrote a while back, which i re-compiled just to make sure this is very frustrating, can anyone think of something that might be

Functionless Errors There are a total of fifty unique WinSock error values. Detailed description: SO_BROADCAST is not supported on sockets of type SOCK_STREAM. Berkeley description: No connection could be made because the target machine actively refused it. Socket Error 11004 A reserved policy element was found in the QoS provider-specific buffer.   Requirements Header Winsock2.h; Winerror.h See also Error Codes - errno, h_errno and WSAGetLastError Handling Winsock Errors FormatMessage WSAGetLastError  

Privacy Policy Site Map Support Terms of Use SolarWinds | Serv-U Contact Support: 866-530-8040 | Contact Sales: 855-498-4154 or email | | Login Products FTP Server MFT Server Purchase FTP Server What Is A Socket Error A connection attempt failed because the connected party did not properly respond after a period of time, or the established connection failed because the connected host has failed to respond. WinSock functions: recv(), recvfrom(), send(), sendto() WSAENAMETOOLONG (10063) File name too long. In some instances, it also refers to the current state of the socket—for instance, calling accept on a socket that is not listening.

Such exclusive access is a new feature of Windows NT 4.0 with SP4 and later, and is implemented by using the SO_EXCLUSIVEADDRUSE option. Socket Error Codes Linux Login. WSANO_RECOVERY 11003 This is a nonrecoverable error. If instead you mean to establish 1000 simultaneous connections, you need to allocate a new socket with socket() on each iteration, connect() it, then go back around again to get another

What Is A Socket Error

The WinSock implementation was unable to allocate additional memory to accommodate the function request. I did not encounter the problem you were encountering when calling select(). Windows Socket Error 10054 Detailed description: recv() and recvfrom(): if the datagram you read is larger than the buffer you supplied, then WinSock truncates the datagram (i.e. Winsock Error 10053 First Name Please enter a first name Last Name Please enter a last name Email We will never share this with anyone.

WSASERVICE_NOT_FOUND 10108 Service not found. check over here Windows Sockets only allows a single blocking operation—per- task or thread—to be outstanding, and if any other function call is made (whether or not it references that or any other socket) Note that this error is returned by the operating system, so the error number may change in future releases of Windows. Berkeley description: The quota system ran out of table entries. Socket Error 10054 Connection Reset By Peer

Note that the v1.1 WinSock specification does not explicitly state that this error occurs if the value you request is larger than the WSAData.iMaxUdpDg returned from WSAStartup(). Does anyone know why?0AcceptEx returns 1022 (WSAEINVAL)… What did I do wrong?1Does blocking code always use return statements and non-blocking code always use a callback?1should be a socket closed ALWAYS if which *might* be nearing the resolution of some internal timer (but I don't know why that would be the case). his comment is here I would expect XP's IPv6 stack to still have bugs as a result, even if you've got all the patches installed.

For example, if a call to WaitForMultipleEvents fails or one of the registry functions fails trying to manipulate the protocol/namespace catalogs. Socket Error 10061 Connection Refused Check Using whois Open your web browser. BUT this month EVERYTHING bombed out on my desktop and I still have not been able to send messages out on my DESKTOP.

Berkeley description: A connection was forcibly closed by a peer.

WinSock functions: accept(), bind(), closesocket(), connect(), gethostbyaddr(), gethostbyname(), gethostname(), getpeername(), getprotobyname(), getprotobynumber(), getservbyname(), getservbyport(), getsockname(), getsockopt(), ioctlsocket(), listen(), recv(), recvfrom(), select(), send(), sendto(), setsockopt(), shutdown(), socket(), WSAAsyncGetHostByAddr(), WSAAsyncGetHostByName(), WSAAsyncGetProtoByName(), WSAAsyncGetProtoByNumber(), WSAAsyncGetServByName(), But I still get the WSAEINVAL error. See also: WSANO_DATA, WSANO_RECOVERY, WSATRY_AGAIN WSANOTINITIALISED (10093) Successful WSAStartup() not yet performed Berkeley description: No equivalent. Socket Error 11001 closesocket(): occurs on a non-blocking socket with non-zero timeout set with setsockopt() SO_LINGER.

Check the destination address you are using. Developer suggestion: are you trying to use an optional feature? SUPPORT Get Support Customer Service Resources Online Community COMPANY About Contact Shop the Serv-U online store, visit the Customer Service Center, or find a reseller. weblink send() & sendto(): socket not bound (for Dgram) or not yet connected (for Stream) The v1.1 specification also has a detailed description for the connect() function which says: "socket not already

A message sent on a datagram socket was larger than the internal message buffer or some other network limit, or the buffer used to receive a datagram was smaller than the WinSock description: Same as Berkeley, and then some. WSAETOOMANYREFS 10059 Too many references. Enter "PING yoursite.com" without the quotes where "yoursite.com" is the name of the server you're connecting to.

Europe roaming from June 2017- single market? It's quite common to enter a domain name incorrectly, so be sure to check this information. <

WinSock description: No equivalent. Detailed description: send() & sendto(): the requested address is a broadcast address, but the appropriate flag was not set (i.e. getaddrinfo is usually used to translate host names to IP addresses, via calling a DNS lookup, and should be followed with freeaddrinfo like you already mentioned.